Share:

GREYMONT ST over SMALL UNNAMED STREAM

Map 

Coordinates:
+32.31333, -90.16778
32°18'48" N, 90°10'04" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:GREYMONT ST over SMALL UNNAMED STREAM
Structure number:SA2500000000265
Location:SEC 35 T 6N R 1E
Purpose:Carries highway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:7.9 ft. [2.4 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1955
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:1,220 [as of 2007]
Truck traffic:8% of total traffic
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:47.5 tons [43.2 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:99.9

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:1,200 [as of 1997]
Truck traffic:8% of total traffic
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:47.5 tons [43.2 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:99.9