Facts 

Name:MCDONALD ROAD over TRIB OF LITTLE CANAL
Structure number:SA6200000000146
Location:SEC 24 T 7N R 9E B
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:40.0 ft. [12.2 m]
Total length:200.1 ft. [61.0 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:31.2 ft. [9.5 m]
Owner:County Highway Agency [02]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2015 

Status:Open, no restriction [A]
Average daily traffic:60 [as of 2012]
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:75.9 tons [69.0 metric tons]
Inventory rating:42.0 tons [38.2 metric tons]
Sufficiency rating:100.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$630,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
December 2015100.0Not deficientVery GoodVery GoodVery Good60
December 2013100.0Not deficientVery GoodVery GoodVery Good60
December 2011100.0Not deficientVery GoodVery GoodVery Good60
December 2009100.0Not deficientVery GoodVery GoodVery Good60
January 2008100.0Not deficientVery GoodVery GoodVery Good60
September 2005100.0Not deficientVery GoodVery GoodVery Good60
December 2003100.0Not deficientVery GoodVery GoodVery Good60
December 2001100.0Not deficientExcellentExcellentExcellent60
December 1999100.0Not deficientExcellentExcellentExcellent60
December 1997100.0Not deficientExcellentExcellentExcellent60