COUNTY ROAD 217 over MUSSELSHELL RIVER 003
Map
Coordinates:
+46.30163, -109.2076946°18'06" N, 109°12'28" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | COUNTY ROAD 217 over MUSSELSHELL RIVER 003 |
| Structure number: | L19217000+03001 |
| Location: | 2M E RYGATE |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Rural) [09] |
| Length of largest span: | 140.1 ft. [42.7 m] |
| Total length: | 140.1 ft. [42.7 m] |
| Roadway width between curbs: | 15.1 ft. [4.6 m] |
| Deck width edge-to-edge: | 15.7 ft. [4.8 m] |
| Vertical clearance above deck: | 15.1 ft. [4.6 m] |
| Owner: | County Highway Agency [02] |
| Year built: | 1911 |
| Year reconstructed: | 1994 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Main span material: | Steel [3] |
| Main span design: | Truss - Thru [10] |
| Deck type: | Wood or Timber [8] |
| Wearing surface: | Wood or Timber [7] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 100 [as of 2003] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
| Operating rating: | 41.9 tons [38.1 metric tons] |
| Inventory rating: | 29.9 tons [27.2 metric tons] |
| Sufficiency rating: | 65.0 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 100 [as of 1995] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 41.9 tons [38.1 metric tons] |
| Inventory rating: | 29.9 tons [27.2 metric tons] |
| Sufficiency rating: | 76.0 |
1992 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 31 [as of 1991] |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 13.3 tons [12.1 metric tons] |
| Inventory rating: | 9.5 tons [8.6 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 23.7 |