Share:

TYVOLA ROAD over SUGAR CREEK

Map 

Coordinates:
+35.18306, -80.91831
35°10'59" N, 80°55'06" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:TYVOLA ROAD over SUGAR CREEK
Structure number:000000001190556
Location:0.1MI.N.PAUL BUCK BLVD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:58.1 ft. [17.7 m]
Total length:242.1 ft. [73.8 m]
Roadway width between curbs:69.9 ft. [21.3 m]
Deck width edge-to-edge:80.7 ft. [24.6 m]
Skew angle:45°
Owner:City or Municipal Highway Agency [04]
Year built:1989
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2014 

Status:Open, no restriction [A]
Average daily traffic:21,000 [as of 2012]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:65.9 tons [59.9 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:96.0

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
June 201496.0Not deficientSatisfactoryGoodGood21000
June 201295.7Not deficientGoodGoodGood22900
June 201095.7Not deficientGoodVery GoodGood22900
July 200895.7Not deficientGoodVery GoodGood22900
June 200695.7Not deficientVery GoodVery GoodVery Good22900
April 200495.7Not deficientVery GoodVery GoodVery Good22900
July 200295.7Not deficientVery GoodVery GoodVery Good22900
July 200094.7Not deficientVery GoodVery GoodVery Good22900
March 199876.9Functionally obsoleteVery GoodVery GoodVery Good22900
May 199077.1Not deficientVery GoodVery GoodVery Good20000