Share:

E.WESTINGHOUSE BLV over KINGS BRANCH

Map 

Coordinates:
+35.11289, -80.89275
35°06'46" N, 80°53'34" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:E.WESTINGHOUSE BLV over KINGS BRANCH
Structure number:000000001191012
Location:.2MI.E.JCT.NATIONS FORD R
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:9.8 ft. [3.0 m]
Total length:33.1 ft. [10.1 m]
Skew angle:20°
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: April 2014 

Status:Open, no restriction [A]
Average daily traffic:17,000 [as of 2012]
Truck traffic:7% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:45.9 tons [41.7 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:70.6

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201470.6Not deficient---17000
April 201273.8Not deficient---1000
April 201084.8Not deficient---1000
April 200884.8Not deficient---1000
April 200684.8Not deficient---1000
May 200484.8Not deficient---1000