Share:

COUNTY HIGHWAY 10 over SHELL CREEK

Map 

Coordinates:
+41.49713, -97.07881
41°29'50" N, 97°04'44" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:COUNTY HIGHWAY 10 over SHELL CREEK
Structure number:C001901915
Location:.5W 2.6N OF SCHUYLER
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:80.1 ft. [24.4 m]
Total length:81.0 ft. [24.7 m]
Roadway width between curbs:15.7 ft. [4.8 m]
Deck width edge-to-edge:15.7 ft. [4.8 m]
Owner:County Highway Agency [02]
Year built:1935
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: August 2015 

Status:Posted for load [P]
Average daily traffic:60 [as of 2003]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Equal to present desirable criteria [8]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:12.0 tons [10.9 metric tons]
Inventory rating:7.0 tons [6.4 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:27.5
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
August 201527.5Functionally obsoleteSatisfactoryFairFair60
September 201327.5Functionally obsoleteGoodFairFair60
October 201123.8Functionally obsoleteSatisfactoryFairSatisfactory60
December 200921.1Structurally deficientFairPoorSatisfactory60
May 200724.5Structurally deficientFairPoorSatisfactory60
December 200422.5Structurally deficientPoorPoorPoor60
December 200222.5Structurally deficientPoorPoorPoor60
November 200039.6Functionally obsoleteFairFairFair60
October 199846.6Functionally obsoleteSatisfactorySatisfactorySatisfactory60
September 199645.6Functionally obsoleteFairSatisfactorySatisfactory60
October 199446.3Functionally obsoleteGoodSatisfactorySatisfactory60
October 199245.4Functionally obsoleteVery GoodSatisfactorySatisfactory60
October 199046.4Functionally obsoleteVery GoodSatisfactorySatisfactory60