COUNTY HIGHWAY over STREAM
Map
Coordinates:
+41.78044, -97.2911041°46'50" N, 97°17'28" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | COUNTY HIGHWAY over STREAM |
| Structure number: | C008400905 |
| Location: | 3W 11.5S OF STANTON |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Rural) [09] |
| Length of largest span: | 20.0 ft. [6.1 m] |
| Total length: | 22.0 ft. [6.7 m] |
| Roadway width between curbs: | 26.2 ft. [8.0 m] |
| Deck width edge-to-edge: | 26.9 ft. [8.2 m] |
| Owner: | County Highway Agency [02] |
| Year built: | 1985 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Main span material: | Concrete [1] |
| Main span design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 25 [as of 2003] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 23.8 tons [21.6 metric tons] |
| Sufficiency rating: | 85.4 |
2000 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 25 [as of 1997] |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Excellent [9 out of 9] |
| Substructure condition: | Excellent [9 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 96.0 |
1992 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 25 [as of 1990] |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Excellent [9 out of 9] |
| Substructure condition: | Excellent [9 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 39.6 tons [36.0 metric tons] |
| Inventory rating: | 18.6 tons [16.9 metric tons] |
| Sufficiency rating: | 82.6 |