Share:

EB-US6/DOUGLAS ST over I480/US75

Map 

Coordinates:
+41.25875, -95.95361
41°15'31" N, 95°57'13" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:EB-US6/DOUGLAS ST over I480/US75
Structure number:S480 00224
Location:IN OMAHA
Purpose:Carries highway overpass over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:111.9 ft. [34.1 m]
Total length:341.9 ft. [104.2 m]
Roadway width between curbs:51.8 ft. [15.8 m]
Deck width edge-to-edge:67.9 ft. [20.7 m]
Vertical clearance below bridge:15.7 ft. [4.8 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1964
Year reconstructed:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:8,880 [as of 2008]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:70.3 tons [63.9 metric tons]
Inventory rating:41.6 tons [37.8 metric tons]
Sufficiency rating:78.9

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:7,263 [as of 1998]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:31.7 tons [28.8 metric tons]
Sufficiency rating:76.9

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:13,400 [as of 1990]
Truck traffic:2% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:31.7 tons [28.8 metric tons]
Sufficiency rating:62.2