Share:

SPENCER STREET over DUCK CREEK

Map 

Coordinates:
+36.05111, -115.12750
36°03'04" N, 115°07'39" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:SPENCER STREET over DUCK CREEK
Structure number:B2077
Location:SOUTHEAST OF LAS VEGAS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:14.1 ft. [4.3 m]
Total length:89.2 ft. [27.2 m]
Roadway width between curbs:67.9 ft. [20.7 m]
Deck width edge-to-edge:76.1 ft. [23.2 m]
Skew angle:40°
Owner:County Highway Agency [02]
Year built:2009
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2013 

Status:Open, no restriction [A]
Average daily traffic:700 [as of 2012]
Truck traffic:1% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:63.0 tons [57.3 metric tons]
Inventory rating:37.7 tons [34.3 metric tons]
Sufficiency rating:98.0

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
November 201398.0Not deficient---700
November 201199.9Not deficient---700
November 200999.9Not deficient---700
November 200797.0Not deficient---660
November 200597.0Not deficient---600
January 200497.0Not deficient---600
January 200297.0Not deficient---600
November 199997.0Not deficient---600
January 199997.0Not deficient---600