SCHUSTER ST over DRY WASH
Map
Coordinates:
+36.06972, -115.1922236°04'11" N, 115°11'32" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | SCHUSTER ST over DRY WASH |
| Structure number: | B2189 |
| Location: | S.W LAS VEGAS |
| Purpose: | Carries highway and pedestrian walkway over waterway |
| Route classification: | Collector (Urban) [17] |
| Length of largest span: | 11.8 ft. [3.6 m] |
| Total length: | 26.2 ft. [8.0 m] |
| Owner: | County Highway Agency [02] |
| Year built: | 1998 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18+Mod / HS 20+Mod [6] |
| Number of main spans: | 2 |
| Main spans material: | Concrete [1] |
| Main spans design: | Culvert [19] |
| Deck type: | Not applicable [N] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 100 [as of 2008] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 77.9 tons [70.8 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Sufficiency rating: | 97.0 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 100 [as of 1998] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Culvert condition: | No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 77.9 tons [70.8 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Sufficiency rating: | 97.0 |