Share:

UNION TURNPIKE EB over RTE I678, RTE I678, RAMP

Map 

Coordinates:
+40.71552, -73.82559
40°42'56" N, 73°49'32" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:UNION TURNPIKE EB over RTE I678, RTE I678, RAMP
Structure number:000000001076049
Location:JCT G C PKWY & I678
Purpose:Carries highway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:50.9 ft. [15.5 m]
Total length:107.0 ft. [32.6 m]
Roadway width between curbs:69.9 ft. [21.3 m]
Deck width edge-to-edge:91.5 ft. [27.9 m]
Vertical clearance above deck:15.1 ft. [4.6 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Skew angle:28°
Owner:State Highway Agency [01]
Year built:1953
Year reconstructed:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: May 2014 

Status:Open, no restriction [A]
Average daily traffic:29,796 [as of 2010]
Truck traffic:7% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:56.9 tons [51.7 metric tons]
Inventory rating:35.0 tons [31.8 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:92.4
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$5,516,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
May 201492.4Functionally obsoleteVery GoodSatisfactorySatisfactory29796
June 201278.1Structurally deficientPoorSatisfactoryFair30100
June 201079.0Structurally deficientPoorSatisfactoryFair14335
June 200877.6Structurally deficientPoorSatisfactoryFair37544
May 200690.1Structurally deficientPoorSatisfactorySatisfactory14335
June 200490.1Structurally deficientPoorSatisfactorySatisfactory14335
June 200290.1Structurally deficientPoorSatisfactorySatisfactory13396
March 200070.9Structurally deficientPoorSatisfactorySatisfactory13396
June 199870.9Structurally deficientPoorSatisfactorySatisfactory13396
June 199643.7Structurally deficientPoorFairPoor13396
April 199443.3Structurally deficientPoorFairPoor18500
June 199243.3Structurally deficientPoorFairPoor18500
October 199043.3Structurally deficientPoorSatisfactoryPoor18500