Share:

CROSBY ROAD over PINE RIDGE BROOK

Map 

Coordinates:
+43.54419, -74.00199
43°32'39" N, 74°00'07" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:CROSBY ROAD over PINE RIDGE BROOK
Structure number:000000002203460
Location:1 MI E OF GARNET LAKE
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:23.0 ft. [7.0 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:13.1 ft. [4.0 m]
Deck width edge-to-edge:16.1 ft. [4.9 m]
Owner:Town or Township Highway Agency [03]
Year built:1905
Year reconstructed:1989
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: August 2015 

Status:Open, no restriction [A]
Average daily traffic:25 [as of 2010]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:72.8 tons [66.2 metric tons]
Inventory rating:43.9 tons [39.9 metric tons]
Sufficiency rating:75.7
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$14,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
August 201575.7Not deficientSatisfactorySatisfactorySatisfactory25
August 201376.7Not deficientSatisfactorySatisfactorySatisfactory25
July 201176.8Not deficientSatisfactorySatisfactorySatisfactory20
July 200976.9Not deficientSatisfactorySatisfactorySatisfactory6
July 200775.9Not deficientSatisfactoryGoodGood6
June 200576.9Not deficientSatisfactoryGoodGood6
July 200377.9Not deficientGoodGoodSatisfactory6
June 200177.9Not deficientGoodGoodSatisfactory6
June 199978.9Not deficientVery GoodVery GoodGood6
June 199777.9Not deficientGoodVery GoodSatisfactory6
July 199550.2Not deficientSatisfactoryVery GoodFair3
May 199339.1Structurally deficientSatisfactoryVery GoodPoor3
July 199124.8Structurally deficientVery GoodSatisfactorySerious3