Share:

RTE 907V over ST CLAIR PLACE, 138THSTT

Map 

Coordinates:
+40.82321, -73.95706
40°49'24" N, 73°57'25" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:RTE 907V over ST CLAIR PLACE, 138THSTT
Structure number:000000002229339
Location:3 MI NE ROUTE 9A+79 ST
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:90.9 ft. [27.7 m]
Total length:4730.2 ft. [1441.7 m]
Roadway width between curbs:71.9 ft. [21.9 m]
Deck width edge-to-edge:78.1 ft. [23.8 m]
Vertical clearance above deck:16.1 ft. [4.9 m]
Vertical clearance below bridge:14.1 ft. [4.3 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1939
Year reconstructed:1982
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:64
Main spans material:Steel [3]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2014 

Status:Open, no restriction [A]
Average daily traffic:132,812 [as of 2009]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Operating rating:49.0 tons [44.5 metric tons]
Inventory rating:26.0 tons [23.6 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:65.5
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$792,800,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201465.5Functionally obsoleteSatisfactorySatisfactorySatisfactory132812
April 201265.5Functionally obsoleteSatisfactorySatisfactorySatisfactory132800
March 201055.5Functionally obsoleteSatisfactoryFairFair132812
May 200855.5Functionally obsoleteSatisfactoryFairFair132812
June 200655.5Functionally obsoleteSatisfactoryFairFair132711
April 200455.5Functionally obsoleteSatisfactoryFairFair130767
April 200239.2Functionally obsoleteSatisfactoryFairFair75188
March 200039.2Functionally obsoleteSatisfactoryFairFair75188
May 199839.2Functionally obsoleteSatisfactoryFairFair71816
June 199650.0Structurally deficientFairPoorPoor87034
June 199444.9Structurally deficientFairFairPoor119135
July 199241.9Structurally deficientFairPoorPoor99433
August 199041.9Structurally deficientPoorPoorPoor99433