Facts 

Name:BRONX BLVD N.B. over BRONX RIVER
Structure number:000000002242072
Location:AT WILLIAMS BRIDGE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:44.0 ft. [13.4 m]
Total length:45.9 ft. [14.0 m]
Roadway width between curbs:25.3 ft. [7.7 m]
Deck width edge-to-edge:39.4 ft. [12.0 m]
Skew angle:13°
Owner:City or Municipal Highway Agency [04]
Year built:1920
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Main span material:Concrete [1]
Main span design:Arch - Deck [11]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2014 

Status:Open, no restriction [A]
Average daily traffic:2,741 [as of 2008]
Truck traffic:13% of total traffic
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:46.8 tons [42.5 metric tons]
Inventory rating:19.9 tons [18.1 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:47.1
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$1,927,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201447.1Functionally obsolete-SatisfactoryFair2741
March 201247.1Functionally obsolete-SatisfactoryFair2750
May 201049.9Functionally obsolete-SatisfactoryFair4900
May 200849.9Functionally obsolete-SatisfactoryFair4900
May 200649.9Functionally obsolete-SatisfactoryFair4900
May 200449.9Functionally obsolete-SatisfactoryFair4900
May 200249.9Functionally obsolete-SatisfactoryFair4900
May 200049.9Functionally obsolete-SatisfactoryFair4900
May 199849.9Functionally obsolete-SatisfactoryFair4900
April 199634.4Structurally deficient-FairPoor4900
May 199431.8Structurally deficient-FairPoor4900
May 199230.7Structurally deficient-FairPoor4900
May 199038.3Structurally deficient-FairPoor4900