Share:

METROPOLITAN AVE over CSX TRANS/CPR&P&W

Map 

Coordinates:
+40.71227, -73.88877
40°42'44" N, 73°53'20" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:METROPOLITAN AVE over CSX TRANS/CPR&P&W
Structure number:000000002247500
Location:IN MIDDLE VILLAGE
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:29.9 ft. [9.1 m]
Total length:35.8 ft. [10.9 m]
Roadway width between curbs:44.9 ft. [13.7 m]
Deck width edge-to-edge:518.1 ft. [157.9 m]
Vertical clearance below bridge:17.4 ft. [5.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1916
Historic significance:Historical significance is not determinable at this time [4]
Main span material:Concrete [1]
Main span design:Frame [07]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2015 

Status:Open, no restriction [A]
Average daily traffic:21,623 [as of 2010]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:49.4 tons [44.9 metric tons]
Inventory rating:14.1 tons [12.8 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:4.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$46,117,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
September 20154.8Structurally deficientSatisfactoryPoorSatisfactory21623
August 201340.2Structurally deficientSatisfactoryPoorSatisfactory21623
October 201136.2Structurally deficientPoorPoorSatisfactory21600
October 200937.2Structurally deficientPoorPoorSatisfactory19617
November 200736.0Structurally deficientPoorPoorSatisfactory22175
August 200558.7Functionally obsoleteFairFairSatisfactory16656
August 200358.7Functionally obsoleteFairFairSatisfactory16656
July 200147.2Structurally deficientGoodPoorFair16656
April 199947.2Structurally deficientGoodPoorFair16656
July 199762.0Functionally obsolete-FairSatisfactory24159
August 199542.2Structurally deficient-PoorPoor24159
November 199345.7Structurally deficient-PoorPoor17000
November 19918.4Structurally deficient-PoorPoor17000