Facts 

Name:BUS RAMP E96 over DYER AVE
Structure number:000000005522460
Location:IN WEST MANHATTAN
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Local (Urban) [19]
Length of largest span:102.7 ft. [31.3 m]
Total length:106.0 ft. [32.3 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Vertical clearance above deck:11.8 ft. [3.6 m]
Vertical clearance below bridge:14.1 ft. [4.3 m]
Skew angle:99°
Owner:Local Toll Authority [32]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: July 2015 

Status:Open, no restriction [A]
Average daily traffic:500 [as of 2009]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:104.5 tons [95.0 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:74.5
Recommended work:Bridge deck rehabilitation with only incidental widening. [36]
Estimated cost of work:$1,121,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
July 201574.5Functionally obsoleteFairSatisfactorySatisfactory500
July 201374.5Functionally obsoleteFairSatisfactorySatisfactory500
July 201174.5Functionally obsoleteFairSatisfactorySatisfactory500
July 200975.5Functionally obsoleteSatisfactorySatisfactorySatisfactory500
November 200775.5Functionally obsoleteSatisfactorySatisfactorySatisfactory500
August 200575.5Functionally obsoleteSatisfactorySatisfactorySatisfactory500
October 200374.5Functionally obsoleteSatisfactorySatisfactorySatisfactory500
October 200174.5Functionally obsoleteSatisfactorySatisfactorySatisfactory500
September 199974.5Functionally obsoleteSatisfactorySatisfactorySatisfactory500
July 199762.5Functionally obsoleteFairSatisfactoryFair500
September 199544.9Structurally deficientPoorFairPoor500
November 199346.9Structurally deficientPoorFairPoor500
September 199144.9Structurally deficientPoorFairPoor500