Share:

RAMP 179 over HENRY HUD PKWY NB, RAMP

Map 

Coordinates:
+40.84957, -73.94121
40°50'58" N, 73°56'28" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:RAMP 179 over HENRY HUD PKWY NB, RAMP
Structure number:00000000552250C
Location:95I OVER HUDSON RIVER
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:94.8 ft. [28.9 m]
Total length:1254.0 ft. [382.2 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:40.4 ft. [12.3 m]
Vertical clearance above deck:17.4 ft. [5.3 m]
Vertical clearance below bridge:14.1 ft. [4.3 m]
Owner:Local Toll Authority [32]
Year built:1931
Year reconstructed:1962
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:50
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: September 2015 

Status:Open, no restriction [A]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:65.0 tons [59.1 metric tons]
Inventory rating:25.9 tons [23.5 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:68.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$49,382,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
September 201568.4Functionally obsoleteFairFairFair-
September 201353.5Functionally obsoleteSatisfactorySatisfactoryFair9633
September 201155.5Functionally obsoleteSatisfactorySatisfactoryFair9633
August 200965.6Functionally obsoleteSatisfactorySatisfactorySatisfactory9633
August 20075.2Functionally obsoleteSatisfactorySatisfactorySatisfactory9633
July 20055.2Functionally obsoleteSatisfactorySatisfactorySatisfactory9633
September 200354.5Functionally obsoleteSatisfactorySatisfactoryFair9633
September 200150.1Functionally obsoleteSatisfactorySatisfactoryFair9633
September 199948.1Functionally obsoleteSatisfactorySatisfactoryFair9633
September 199721.1Structurally deficientFairPoorFair167163
October 199519.0Structurally deficientPoorPoorPoor167163
September 199317.4Structurally deficientFairPoorPoor167163
August 199129.1Structurally deficientFairFairPoor167163