Share:

I-70 WEST BOUND over I-70 OVER CR 15

Map 

Coordinates:
+40.00833, -81.61583
40°00'30" N, 81°36'57" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I-70 WEST BOUND over I-70 OVER CR 15
Structure number:3001024
Location:.4 M E OF JCT SR 723
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:43.0 ft. [13.1 m]
Total length:114.2 ft. [34.8 m]
Roadway width between curbs:41.0 ft. [12.5 m]
Deck width edge-to-edge:44.3 ft. [13.5 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Skew angle:20°
Owner:State Highway Agency [01]
Year built:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:17,685 [as of 2008]
Truck traffic:36% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:90.2

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:13,990 [as of 1996]
Truck traffic:32% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:90.6

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:11,910 [as of 1987]
Truck traffic:30% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:59.4 tons [54.0 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:91.0