Share:

SOUTH BOUND I-77 over I-77 OVER CR 35

Map 

Coordinates:
+40.09722, -81.56000
40°05'50" N, 81°33'36" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:SOUTH BOUND I-77 over I-77 OVER CR 35
Structure number:3003248
Location:3.5 M N OF JCT US 22
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:55.1 ft. [16.8 m]
Total length:145.0 ft. [44.2 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:42.3 ft. [12.9 m]
Vertical clearance below bridge:15.7 ft. [4.8 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1968
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:9,535 [as of 2008]
Truck traffic:30% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:89.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:8,910 [as of 1996]
Truck traffic:24% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:90.1

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:5,620 [as of 1987]
Truck traffic:25% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:59.4 tons [54.0 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:88.5