COLUMBIA PARKWAY over IR471,RAMP,EGG,CUL
Map
Coordinates:
+39.10194, -84.5011139°06'07" N, 84°30'04" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | COLUMBIA PARKWAY over IR471,RAMP,EGG,CUL |
| Structure number: | 3103390 |
| Location: | N OF I471 & US50 INT |
| Purpose: | Carries highway over highway |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 170.0 ft. [51.8 m] |
| Total length: | 1659.2 ft. [505.7 m] |
| Roadway width between curbs: | 56.1 ft. [17.1 m] |
| Deck width edge-to-edge: | 71.9 ft. [21.9 m] |
| Vertical clearance below bridge: | 24.9 ft. [7.6 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1938 |
| Year reconstructed: | 1997 |
| Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
| Design load: | MS 18+Mod / HS 20+Mod [6] |
| Number of main spans: | 7 |
| Main spans material: | Steel [3] |
| Main spans design: | Truss - Deck [09] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 56,580 [as of 2005] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 32.7 tons [29.7 metric tons] |
| Inventory rating: | 23.8 tons [21.6 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 67.5 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 100 [as of 1996] |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 32.7 tons [29.7 metric tons] |
| Inventory rating: | 23.8 tons [21.6 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 82.4 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
| Estimated cost of work: | $2,750,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 100 [as of 1988] |
| Deck condition: | Serious [3 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 39.6 tons [36.0 metric tons] |
| Inventory rating: | 23.8 tons [21.6 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 65.4 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
| Estimated cost of work: | $2,750,000 |