CUTNAW RD. over CLEAR FORK MOHICAN RIVER
Map
Coordinates:
+40.58500, -82.4600040°35'06" N, 82°27'36" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | CUTNAW RD. over CLEAR FORK MOHICAN RIVER |
| Structure number: | 7034032 |
| Location: | INT.OF GATTON ROCKS RD. |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Rural) [09] |
| Length of largest span: | 52.2 ft. [15.9 m] |
| Total length: | 107.0 ft. [32.6 m] |
| Roadway width between curbs: | 29.9 ft. [9.1 m] |
| Deck width edge-to-edge: | 29.9 ft. [9.1 m] |
| Owner: | County Highway Agency [02] |
| Year built: | 1992 |
| Historic significance: | Historical significance is not determinable at this time [4] |
| Design load: | MS 18+Mod / HS 20+Mod [6] |
| Number of main spans: | 2 |
| Main spans material: | Prestressed concrete [5] |
| Main spans design: | Box beam or girders - Multiple [05] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 255 [as of 1992] |
| Truck traffic: | 25% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 99.9 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 255 [as of 1992] |
| Truck traffic: | 25% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4] |
| Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 99.9 |