Facts 

Name:ARMSTRONG RD. over PLEASANT VALLEY RUN
Structure number:7034598
Location:0.6M S OF SR 95
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:21.0 ft. [6.4 m]
Total length:23.0 ft. [7.0 m]
Owner:County Highway Agency [02]
Year built:1986
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Aluminum, Wrought Iron or Cast Iron [9]
Main span design:Culvert [19]
Deck type:Not applicable [N]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:485 [as of 1991]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:96.8

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:485 [as of 1991]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:96.8

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:485 [as of 1991]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:50.5 tons [45.9 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]