BAKERS FERRY RD over CLACKAMAS RIVER
Map
Coordinates:
+45.38191, -122.4136045°22'55" N, 122°24'49" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | BAKERS FERRY RD over CLACKAMAS RIVER |
| Structure number: | 06560 019 00341 |
| Location: | 5.1 MI EAST OF CARVER |
| Purpose: | Carries highway and pedestrian walkway over waterway |
| Route classification: | Major Collector (Rural) [07] |
| Length of largest span: | 180.1 ft. [54.9 m] |
| Total length: | 880.0 ft. [268.2 m] |
| Roadway width between curbs: | 25.9 ft. [7.9 m] |
| Deck width edge-to-edge: | 33.5 ft. [10.2 m] |
| Vertical clearance above deck: | 15.1 ft. [4.6 m] |
| Owner: | County Highway Agency [02] |
| Year built: | 1970 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Main span material: | Steel [3] |
| Main span design: | Arch - Thru [12] |
| Deck type: | Concrete Precast Panels [2] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,029 [as of 2007] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
| Operating rating: | 32.9 tons [29.9 metric tons] |
| Inventory rating: | 24.0 tons [21.8 metric tons] |
| Sufficiency rating: | 58.1 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 960 [as of 1998] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
| Operating rating: | 32.7 tons [29.7 metric tons] |
| Inventory rating: | 23.8 tons [21.6 metric tons] |
| Sufficiency rating: | 66.2 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 850 [as of 1990] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 32.7 tons [29.7 metric tons] |
| Inventory rating: | 23.8 tons [21.6 metric tons] |
| Sufficiency rating: | 52.3 |