COLUMBIA BLVD over B-103 X NE 33RD AVE
Map
Coordinates:
+45.57350, -122.6298445°34'25" N, 122°37'47" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | COLUMBIA BLVD over B-103 X NE 33RD AVE |
| Structure number: | 51C33 000 00001 |
| Location: | IN NE PORTLAND |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 40.0 ft. [12.2 m] |
| Total length: | 101.1 ft. [30.8 m] |
| Roadway width between curbs: | 71.9 ft. [21.9 m] |
| Deck width edge-to-edge: | 82.0 ft. [25.0 m] |
| Vertical clearance below bridge: | 17.1 ft. [5.2 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1963 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Concrete continuous [2] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 28,802 [as of 2007] |
| Truck traffic: | 20% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 35.0 tons [31.8 metric tons] |
| Inventory rating: | 21.0 tons [19.1 metric tons] |
| Sufficiency rating: | 74.7 |
2000 Inspection
| Status: | Open, posting recommended but not legally implemented [B] |
| Average daily traffic: | 25,600 [as of 1997] |
| Truck traffic: | 20% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 34.7 tons [31.5 metric tons] |
| Inventory rating: | 20.8 tons [18.9 metric tons] |
| Sufficiency rating: | 76.7 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $1,329,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 25,800 [as of 1989] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 30.4 tons [27.6 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 94.0 |