Share:

SAW MILL RUN BL over SAW MILL RUN

Map 

Coordinates:
+40.39597, -79.99817
40°23'45" N, 79°59'53" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:SAW MILL RUN BL over SAW MILL RUN
Structure number:000000000000738
Old structure number:020051036005680 (from 1992 edition)
Location:AT WHITED STREET
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:55.1 ft. [16.8 m]
Total length:60.0 ft. [18.3 m]
Roadway width between curbs:45.9 ft. [14.0 m]
Deck width edge-to-edge:61.0 ft. [18.6 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1929
Year reconstructed:1941
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2015 

Status:Open, no restriction [A]
Average daily traffic:42,233 [as of 2015]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:62.9 tons [57.2 metric tons]
Inventory rating:37.0 tons [33.6 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:52.0
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
February 201552.0Functionally obsoleteFairFairFair42233
February 201352.0Functionally obsoleteFairSatisfactoryFair42698
February 201152.0Functionally obsoleteFairSatisfactoryFair28232
February 200952.0Functionally obsoleteFairSatisfactoryFair28232
February 200750.0Functionally obsoleteFairSatisfactoryFair54728
February 200549.8Functionally obsoleteFairSatisfactoryFair54186
February 200352.6Functionally obsoleteFairSatisfactoryFair30652
February 200149.9Functionally obsoleteFairSatisfactoryFair30109
February 199952.3Functionally obsoleteFairSatisfactoryFair30109
February 199748.7Functionally obsoleteFairSatisfactoryFair38029
February 199549.0Functionally obsoleteFairSatisfactoryFair37102
February 199349.0Functionally obsoleteFairSatisfactoryFair40798