Share:

SR 0065 SB over FONTELLA ST.

Map 

Coordinates:
+40.44872, -80.01964
40°26'55" N, 80°01'11" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:SR 0065 SB over FONTELLA ST.
Structure number:020065000503560
Location:TR 65 SB O/FONTELLA ST.
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:105.0 ft. [32.0 m]
Total length:626.0 ft. [190.8 m]
Roadway width between curbs:51.8 ft. [15.8 m]
Deck width edge-to-edge:64.0 ft. [19.5 m]
Vertical clearance below bridge:14.8 ft. [4.5 m]
Owner:State Highway Agency [01]
Year built:1991
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:6
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:21,015 [as of 2008]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Inventory rating:21.0 tons [19.1 metric tons]
Sufficiency rating:74.9
Estimated cost of work:$1,000

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:18,234 [as of 2000]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Inventory rating:20.8 tons [18.9 metric tons]
Sufficiency rating:75.3
Estimated cost of work:$741,000