Share:

PENN LINCOLN PKWY over BATES STREET

Map 

Coordinates:
+40.43150, -79.95888
40°25'53" N, 79°57'32" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:PENN LINCOLN PKWY over BATES STREET
Structure number:000000000001152
Old structure number:020376002417350 (from 1992 edition)
Location:BATES ST. INTERCHANGE
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:76.1 ft. [23.2 m]
Total length:195.9 ft. [59.7 m]
Roadway width between curbs:88.9 ft. [27.1 m]
Deck width edge-to-edge:95.5 ft. [29.1 m]
Vertical clearance below bridge:17.1 ft. [5.2 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1952
Year reconstructed:1981
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2015 

Status:Open, no restriction [A]
Average daily traffic:46,989 [as of 2015]
Truck traffic:8% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:62.9 tons [57.2 metric tons]
Inventory rating:38.0 tons [34.5 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:74.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
September 201574.7Functionally obsoleteSatisfactorySatisfactorySatisfactory46989
September 201377.3Not deficientSatisfactorySatisfactorySatisfactory49550
September 201183.5Not deficientSatisfactorySatisfactorySatisfactory25535
September 200981.3Not deficientSatisfactorySatisfactorySatisfactory34061
September 200777.0Not deficientSatisfactorySatisfactorySatisfactory119020
September 200578.0Not deficientSatisfactorySatisfactorySatisfactory108814
September 200378.0Not deficientSatisfactorySatisfactorySatisfactory101211
September 200178.0Not deficientSatisfactorySatisfactorySatisfactory100621
September 199978.0Not deficientSatisfactorySatisfactorySatisfactory106433
September 199778.0Not deficientSatisfactorySatisfactorySatisfactory102001