SIXTH STREET BR over 10TH ST BYPASS,ALLEGH RV
Map
Coordinates:
+40.44434, -80.0028340°26'40" N, 80°00'10" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | SIXTH STREET BR over 10TH ST BYPASS,ALLEGH RV |
| Structure number: | 027301000020120 |
| Location: | AL02 6 ST TO NORTH SIDE |
| Purpose: | Carries highway and pedestrian walkway over highway and waterway |
| Route classification: | Minor Arterial (Urban) [16] |
| Length of largest span: | 430.1 ft. [131.1 m] |
| Total length: | 995.1 ft. [303.3 m] |
| Roadway width between curbs: | 38.1 ft. [11.6 m] |
| Deck width edge-to-edge: | 38.1 ft. [11.6 m] |
| Vertical clearance above deck: | 16.4 ft. [5.0 m] |
| Vertical clearance below bridge: | 621.4 ft. [189.4 m] |
| Owner: | County Highway Agency [02] |
| Year built: | 1928 |
| Year reconstructed: | 1995 |
| Historic significance: | Bridge is on the National Register of Historic Places [1] |
| Design load: | M 13.5 / H 15 [2] |
| Number of main spans: | 3 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Suspension [13] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 12,824 [as of 2005] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Pier/abutment protection: | None present but re-evaluation suggested [5] |
| Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
| Operating rating: | 56.9 tons [51.7 metric tons] |
| Inventory rating: | 33.9 tons [30.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 56.3 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $3,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 12,824 [as of 1999] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Pier/abutment protection: | None present but re-evaluation suggested [5] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 53.5 tons [48.6 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 67.4 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $3,488,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 12,824 [as of 1991] |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 53.5 tons [48.6 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 55.4 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $3,492,000 |