PENNSYLVANIA AV over NORFOLK SOUTHERN RR
Map
Coordinates:
+40.45560, -80.0180440°27'20" N, 80°01'05" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | PENNSYLVANIA AV over NORFOLK SOUTHERN RR |
| Structure number: | 027301000030750 |
| Location: | 301075 PENNSYLVANIA AVE |
| Purpose: | Carries highway and pedestrian walkway over railroad |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 144.0 ft. [43.9 m] |
| Total length: | 152.9 ft. [46.6 m] |
| Roadway width between curbs: | 45.9 ft. [14.0 m] |
| Deck width edge-to-edge: | 60.0 ft. [18.3 m] |
| Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
| Skew angle: | 43° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1986 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Steel [3] |
| Main span design: | Girder and floorbeam system [03] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 10,125 [as of 2004] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 92.8 tons [84.4 metric tons] |
| Inventory rating: | 55.9 tons [50.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 63.6 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 10,125 [as of 1998] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 92.1 tons [83.7 metric tons] |
| Inventory rating: | 55.4 tons [50.4 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 79.2 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
| Estimated cost of work: | $488,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 10,000 [as of 1991] |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 92.1 tons [83.7 metric tons] |
| Inventory rating: | 55.4 tons [50.4 metric tons] |
| Sufficiency rating: | 74.9 |
| Estimated cost of work: | $415,000 |