Share:

BECKS RUN RD over BECKS RUN

Map 

Coordinates:
+40.41022, -79.95901
40°24'37" N, 79°57'32" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:BECKS RUN RD over BECKS RUN
Structure number:000000000002504
Old structure number:027301502420310 (from 1992 edition)
Location:BC01 BECKS RUN NO. 1
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:21.0 ft. [6.4 m]
Total length:21.0 ft. [6.4 m]
Roadway width between curbs:32.5 ft. [9.9 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Skew angle:30°
Owner:County Highway Agency [02]
Year built:1946
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2014 

Status:Open, no restriction [A]
Average daily traffic:13,104 [as of 2006]
Truck traffic:6% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:98.8 tons [89.8 metric tons]
Inventory rating:63.8 tons [58.0 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:70.0

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
May 201470.0Functionally obsolete---13104
May 201270.0Functionally obsolete---13104
May 201070.0Functionally obsolete---13104
May 200870.0Functionally obsolete---13104
May 200670.0Functionally obsolete---13104
July 200470.0Functionally obsolete---13104
September 200271.1Functionally obsolete---13104
October 200071.1Functionally obsolete---13104
November 199870.0Functionally obsolete---13104
November 199670.0Functionally obsolete---13104
November 199466.9Functionally obsolete---13104
September 199267.1Functionally obsolete---12757
October 199066.9Functionally obsolete---13104