Share:

TRAFFIC ROUTE 13 over TYBURN ROAD

Map 

Coordinates:
+40.18132, -74.80900
40°10'53" N, 74°48'32" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:TRAFFIC ROUTE 13 over TYBURN ROAD
Structure number:000000000006773
Old structure number:090013031017030 (from 1992 edition)
Location:2MI.S.MORRISVILL 38H09
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:75.1 ft. [22.9 m]
Total length:148.0 ft. [45.1 m]
Roadway width between curbs:71.5 ft. [21.8 m]
Deck width edge-to-edge:77.4 ft. [23.6 m]
Vertical clearance below bridge:13.8 ft. [4.2 m]
Skew angle:14°
Owner:State Highway Agency [01]
Year built:1954
Year reconstructed:2005
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2015 

Status:Open, no restriction [A]
Average daily traffic:21,726 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:68.9 tons [62.6 metric tons]
Inventory rating:40.9 tons [37.2 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:80.0
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$2,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201580.0Functionally obsoleteGoodFairGood21726
March 201380.0Functionally obsoleteGoodFairGood24658
March 201178.0Not deficientGoodFairGood11368
March 200989.0Not deficientGoodSatisfactoryGood11398
March 200789.0Not deficientGoodSatisfactoryGood23875
March 200589.0Not deficientGoodSatisfactoryGood25653
July 200445.0Structurally deficientGoodFairSerious25299
June 200240.0Structurally deficientPoorFairSerious24389
June 200040.0Structurally deficientPoorFairSerious25001
June 199742.0Structurally deficientFairFairSerious24607
June 199559.0Structurally deficientFairSatisfactoryPoor27615