Share:

SR 1011 over GENESEE RIVER

Map 

Coordinates:
+41.97575, -77.85674
41°58'33" N, 77°51'24" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:SR 1011 over GENESEE RIVER
Structure number:521011015007760
Location:1 MI S GENESEE
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:71.9 ft. [21.9 m]
Total length:75.1 ft. [22.9 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:30.8 ft. [9.4 m]
Owner:State Highway Agency [01]
Year built:1953
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Closed Grating [4]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:510 [as of 2009]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:56.9 tons [51.7 metric tons]
Inventory rating:33.9 tons [30.8 metric tons]
Sufficiency rating:83.3
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$1,000

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:641 [as of 2000]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:51.5 tons [46.8 metric tons]
Inventory rating:29.7 tons [27.0 metric tons]
Sufficiency rating:77.8
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$516,000

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:816 [as of 1992]
Deck condition:Poor [4 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:51.5 tons [46.8 metric tons]
Inventory rating:29.7 tons [27.0 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:79.3
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$211,000