Share:

SPRING GARDEN E.B. over WEST RIVER DRIVE RAMP

Map 

Coordinates:
+39.96437, -75.18327
39°57'52" N, 75°10'60" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:SPRING GARDEN E.B. over WEST RIVER DRIVE RAMP
Structure number:000000000038973
Old structure number:673014004004500 (from 1992 edition)
Location:PHILA.ART MUSEUM 3590A06
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:71.9 ft. [21.9 m]
Total length:76.1 ft. [23.2 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:35.4 ft. [10.8 m]
Vertical clearance below bridge:12.5 ft. [3.8 m]
Skew angle:50°
Owner:State Highway Agency [01]
Year built:1965
Year reconstructed:1981
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2014 

Status:Open, no restriction [A]
Average daily traffic:7,712 [as of 2014]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:98.8 tons [89.8 metric tons]
Inventory rating:65.8 tons [59.8 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:72.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
February 201472.0Functionally obsoleteSatisfactorySatisfactorySatisfactory7712
February 201272.0Functionally obsoleteSatisfactorySatisfactorySatisfactory7794
March 201075.1Functionally obsoleteSatisfactorySatisfactorySatisfactory10785
March 200875.1Functionally obsoleteSatisfactorySatisfactorySatisfactory10761
April 200670.9Functionally obsoleteGoodSatisfactorySatisfactory10610
March 200472.1Functionally obsoleteGoodSatisfactorySatisfactory12704
March 200272.3Functionally obsoleteGoodSatisfactorySatisfactory12247
October 199971.8Functionally obsoleteGoodGoodSatisfactory5742
October 199770.8Functionally obsoleteGoodGoodSatisfactory8404