Share:

2nd Street over AMTRAK (NE CORRIDOR)

Map 

Coordinates:
+40.00524, -75.13193
40°00'19" N, 75°07'55" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:2nd Street over AMTRAK (NE CORRIDOR)
Structure number:000000000039093
Old structure number:677301000202300 (from 1992 edition)
Location:N of Venango Street 29A02
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Collector (Urban) [17]
Length of largest span:85.0 ft. [25.9 m]
Total length:86.9 ft. [26.5 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Vertical clearance above deck:26.2 ft. [8.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:10°
Owner:City or Municipal Highway Agency [04]
Year built:1926
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2015 

Status:Open, no restriction [A]
Average daily traffic:14,600 [as of 1980]
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Serious [3 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Operating rating:93.8 tons [85.3 metric tons]
Inventory rating:38.0 tons [34.5 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:45.2
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$1,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
July 201545.2Structurally deficientPoorPoorSerious14600
July 201345.2Structurally deficientPoorPoorSerious14600
July 201145.2Structurally deficientPoorPoorSerious14600
July 200945.2Structurally deficientPoorPoorSerious14600
July 200745.2Structurally deficientPoorPoorSerious14600
July 200525.2Structurally deficientPoorPoorSerious14600
July 200326.5Structurally deficientPoorPoorSerious14600
July 200126.5Structurally deficientPoorPoorSerious14600
July 199926.5Structurally deficientPoorPoorSerious14600
July 199747.8Structurally deficientPoorPoorSerious14600
July 199544.1Structurally deficientPoorPoorSerious14600
July 199344.1Structurally deficientPoorPoorSerious14600
July 199160.1Structurally deficientPoorPoorPoor14600