RAMP D-DE S.B.OFF over FRONT STREET,RAMP E-DE
Map
Coordinates:
+39.96541, -75.1372939°57'55" N, 75°08'14" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | RAMP D-DE S.B.OFF over FRONT STREET,RAMP E-DE |
| Structure number: | 678003052005030 |
| Location: | WALT WHITMAN BRG. 37H07 |
| Purpose: | Carries highway over highway |
| Route classification: | Collector (Urban) [17] |
| Length of largest span: | 100.1 ft. [30.5 m] |
| Total length: | 1189.0 ft. [362.4 m] |
| Roadway width between curbs: | 46.9 ft. [14.3 m] |
| Deck width edge-to-edge: | 50.9 ft. [15.5 m] |
| Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1974 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | M 13.5 / H 15 [2] |
| Number of main spans: | 3 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 134 [as of 2010] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Poor [4 out of 9] |
| Substructure condition: | Poor [4 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 59.8 tons [54.4 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 70.9 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $1,000 |
2000 Inspection
| Average daily traffic: | 6,800 [as of 1980] |
| Evaluation: | Not applicable [N] |