Share:

RAMP E S.B. OFF over INTERSTATE 95,RAMPS X,Y

Map 

Coordinates:
+39.99667, -75.08333
39°59'48" N, 75°04'60" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:RAMP E S.B. OFF over INTERSTATE 95,RAMPS X,Y
Structure number:000000000039383
Old structure number:678017052000000 (from 1992 edition)
Location:(BRI) RAMP E 3591G01
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:94.2 ft. [28.7 m]
Total length:1971.2 ft. [600.8 m]
Roadway width between curbs:30.2 ft. [9.2 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:12
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2013 

Status:Open, no restriction [A]
Average daily traffic:8,428 [as of 2014]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:74.8 tons [68.0 metric tons]
Inventory rating:32.9 tons [29.9 metric tons]
Sufficiency rating:82.9
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$2,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
November 201382.9Not deficientFairFairFair8428
November 201183.4Not deficientFairFairFair7134
November 200974.2Not deficientFairFairFair25527
November 200774.2Not deficientFairFairFair25420
November 200574.4Not deficientFairFairFair25000