Share:

RAMP'KK'(SB - OFF) over I-95;INDUSTRIAL HWY;RAMP

Map 

Coordinates:
+39.87833, -75.25333
39°52'42" N, 75°15'12" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:RAMP'KK'(SB - OFF) over I-95;INDUSTRIAL HWY;RAMP
Structure number:000000000039439
Old structure number:678047002026110 (from 1992 edition)
Location:N.HIGH SPEED LINE 3698K10
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:134.8 ft. [41.1 m]
Total length:1060.1 ft. [323.1 m]
Roadway width between curbs:41.3 ft. [12.6 m]
Deck width edge-to-edge:43.6 ft. [13.3 m]
Vertical clearance below bridge:13.8 ft. [4.2 m]
Skew angle:14°
Owner:State Highway Agency [01]
Year built:1983
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2014 

Status:Open, no restriction [A]
Average daily traffic:3,320 [as of 2014]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:78.8 tons [71.6 metric tons]
Inventory rating:19.9 tons [18.1 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:75.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
June 201475.8Functionally obsoleteGoodSatisfactorySatisfactory3320
June 201275.4Functionally obsoleteGoodSatisfactorySatisfactory3984
June 201095.4Functionally obsoleteGoodSatisfactorySatisfactory4074
June 200895.9Functionally obsoleteGoodSatisfactorySatisfactory522
March 200693.9Functionally obsoleteGoodSatisfactoryGood512
March 200480.1Not deficientGoodSatisfactoryGood500
March 200277.4Not deficientGoodGoodGood9900