S-5-34 over SYKES BRANCH
Map
Coordinates:
+33.36054, -81.1739333°21'38" N, 81°10'26" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | S-5-34 over SYKES BRANCH |
| Structure number: | 000570003400100 |
| Location: | 3.0MI NW DENMARK |
| Purpose: | Carries highway over waterway |
| Route classification: | Minor Collector (Rural) [08] |
| Length of largest span: | 15.1 ft. [4.6 m] |
| Total length: | 29.9 ft. [9.1 m] |
| Roadway width between curbs: | 31.5 ft. [9.6 m] |
| Deck width edge-to-edge: | 33.1 ft. [10.1 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1971 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | M 13.5 / H 15 [2] |
| Number of main spans: | 2 |
| Main spans material: | Concrete [1] |
| Main spans design: | Slab [01] |
| Deck type: | Concrete Precast Panels [2] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 400 [as of 2008] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 43.6 tons [39.6 metric tons] |
| Inventory rating: | 25.7 tons [23.4 metric tons] |
| Sufficiency rating: | 88.2 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 350 [as of 1997] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 46.9 tons [42.6 metric tons] |
| Inventory rating: | 27.8 tons [25.3 metric tons] |
| Sufficiency rating: | 90.8 |
| Estimated cost of work: | $14,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 180 [as of 1988] |
| Truck traffic: | 4% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 42.6 tons [38.7 metric tons] |
| Inventory rating: | 26.7 tons [24.3 metric tons] |
| Sufficiency rating: | 89.5 |
| Estimated cost of work: | $14,000 |