Share:

NFA C596 over PITTS BRANCH

Map 

Coordinates:
+35.18306, -85.25000
35°10'59" N, 85°15'00" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:NFA C596 over PITTS BRANCH
Structure number:330C5960001
Location:.2 MI WEST OF SR 153
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:30.8 ft. [9.4 m]
Total length:48.2 ft. [14.7 m]
Roadway width between curbs:19.4 ft. [5.9 m]
Deck width edge-to-edge:22.0 ft. [6.7 m]
Skew angle:12°
Owner:City or Municipal Highway Agency [04]
Year built:1950
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 9 / H 10 [1]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Posted for load [P]
Average daily traffic:120 [as of 2010]
Truck traffic:2% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:43.6 tons [39.6 metric tons]
Inventory rating:23.8 tons [21.6 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:49.4
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$131,000

2000 Inspection 

Status:Posted for load [P]
Average daily traffic:120 [as of 1998]
Truck traffic:2% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:43.6 tons [39.6 metric tons]
Inventory rating:23.8 tons [21.6 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:52.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$197,000

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:600 [as of 1978]
Truck traffic:2% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:43.6 tons [39.6 metric tons]
Inventory rating:23.8 tons [21.6 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:49.2
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$93,000