Share:

FAU 3773 over LOVES CREEK

Map 

Coordinates:
+36.03333, -83.86944
36°01'60" N, 83°52'10" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FAU 3773 over LOVES CREEK
Structure number:47037730005
Location:ON CITY LIMITS
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:20.0 ft. [6.1 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:25.6 ft. [7.8 m]
Skew angle:15°
Owner:City or Municipal Highway Agency [04]
Year built:1940
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2014 

Status:Open, no restriction [A]
Average daily traffic:17,190 [as of 2015]
Truck traffic:2% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:39.6 tons [36.0 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:70.0
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$193,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
May 201470.0Functionally obsolete---17190
May 201270.0Functionally obsolete---17190
May 201070.0Functionally obsolete---17190
May 200870.0Functionally obsolete---17190
May 200667.1Functionally obsolete---16460
June 200467.3Functionally obsolete---15480
April 200267.7Functionally obsolete---13820
March 200066.2Functionally obsolete---15940
July 199866.2Functionally obsolete---15870
January 199667.0Functionally obsolete---11060
September 199367.7Functionally obsolete---8050
October 199167.7Functionally obsolete---8100