NFA A115 over BUFFAT MILL DR. / I640
Map
Coordinates:
+36.02778, -83.8658336°01'40" N, 83°51'57" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | NFA A115 over BUFFAT MILL DR. / I640 |
| Structure number: | 47I06400031 |
| Location: | 1 M N OF I640-I40 JCT |
| Purpose: | Carries highway over highway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 137.1 ft. [41.8 m] |
| Total length: | 339.9 ft. [103.6 m] |
| Roadway width between curbs: | 47.9 ft. [14.6 m] |
| Deck width edge-to-edge: | 49.9 ft. [15.2 m] |
| Vertical clearance below bridge: | 17.4 ft. [5.3 m] |
| Skew angle: | 15° |
| Owner: | State Highway Agency [01] |
| Year built: | 1981 |
| Historic significance: | Historical significance is not determinable at this time [4] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Concrete continuous [2] |
| Main spans design: | Box beam or girders - Multiple [05] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,430 [as of 2010] |
| Truck traffic: | 2% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.5 tons [44.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 97.8 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 2000] |
| Truck traffic: | 2% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.5 tons [44.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 99.9 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 1982] |
| Truck traffic: | 2% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.5 tons [44.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 99.9 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $1,224,000 |