FAP 33 over FIRST CREEK
Map
Coordinates:
+36.00444, -83.9266736°00'16" N, 83°55'36" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | FAP 33 over FIRST CREEK |
| Structure number: | 47SR0330021 |
| Location: | 3.1 M SE OF KNOXVILLE |
| Purpose: | Carries highway and pedestrian walkway over waterway |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 28.2 ft. [8.6 m] |
| Total length: | 56.8 ft. [17.3 m] |
| Roadway width between curbs: | 54.5 ft. [16.6 m] |
| Deck width edge-to-edge: | 66.3 ft. [20.2 m] |
| Skew angle: | 15° |
| Owner: | State Highway Agency [01] |
| Year built: | 1936 |
| Historic significance: | Historical significance is not determinable at this time [4] |
| Design load: | M 13.5 / H 15 [2] |
| Number of main spans: | 2 |
| Main spans material: | Concrete [1] |
| Main spans design: | Tee beam [04] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 25,070 [as of 2009] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 54.5 tons [49.5 metric tons] |
| Inventory rating: | 32.7 tons [29.7 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 61.6 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $1,399,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 26,430 [as of 1999] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 54.5 tons [49.5 metric tons] |
| Inventory rating: | 32.7 tons [29.7 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 60.6 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $553,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 26,260 [as of 1991] |
| Truck traffic: | 1% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 86.1 tons [78.3 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 51.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $206,000 |