Facts 

Name:FAU 2878 over BRANCH
Structure number:79028780005
Location:COLEMAN RD - MEMPHIS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:22.0 ft. [6.7 m]
Total length:22.0 ft. [6.7 m]
Skew angle:30°
Owner:City or Municipal Highway Agency [04]
Year built:1963
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: April 2015 

Status:Open, no restriction [A]
Average daily traffic:16,390 [as of 2016]
Truck traffic:4% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:56.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$475,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201556.0Not deficient---16390
April 201356.0Not deficient---16390
May 201156.0Not deficient---16390
July 200956.0Not deficient---16390
October 200767.0Not deficient---16390
October 200567.0Not deficient---20740
October 200367.0Not deficient---20940
November 200167.0Not applicable---20470
March 200067.0Not applicable---19810
April 199867.0Not applicable---18190
June 199867.0Not applicable---18350
December 199567.0Not deficient---17540
October 199367.0Not deficient---18100
December 199170.7Not deficient---6210