Share:

FAU 2813 over BRANCH

Map 

Coordinates:
+35.05389, -90.02222
35°03'14" N, 90°01'20" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FAU 2813 over BRANCH
Structure number:79S81000005
Location:WINCHESTER RD - MEMPHIS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:9.8 ft. [3.0 m]
Total length:23.0 ft. [7.0 m]
Skew angle:15°
Owner:City or Municipal Highway Agency [04]
Year built:1963
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: April 2015 

Status:Open, no restriction [A]
Average daily traffic:21,590 [as of 2016]
Truck traffic:4% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:98.9 tons [89.9 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:72.2
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$541,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201572.2Not deficient---21590
April 201372.2Not deficient---21590
May 201172.2Not deficient---21590
June 200972.2Not deficient---21590
September 200772.2Not deficient---21590
September 200571.3Not deficient---23410
October 200370.5Not deficient---25210
October 200170.0Not deficient---26450
March 200069.9Not deficient---26510
June 199870.8Not deficient---24590
October 199569.1Not deficient---28370
October 199369.2Not deficient---28210
December 199170.8Not deficient---24670