Share:

FAU 2872 over DAYS CREEK

Map 

Coordinates:
+35.03528, -90.00000
35°02'07" N, 90°00'00" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FAU 2872 over DAYS CREEK
Structure number:79S82420003
Location:RAINES RD - MEMPHIS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:77.1 ft. [23.5 m]
Total length:78.1 ft. [23.8 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:76.1 ft. [23.2 m]
Owner:City or Municipal Highway Agency [04]
Year built:1985
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2015 

Status:Open, no restriction [A]
Average daily traffic:14,820 [as of 2016]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:81.3
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$388,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201581.3Functionally obsoleteGoodGoodGood14820
April 201381.3Functionally obsoleteGoodGoodGood14820
May 201181.3Functionally obsoleteGoodGoodGood14820
June 200981.3Functionally obsoleteGoodGoodGood14820
October 200781.3Functionally obsoleteGoodGoodGood14820
September 200578.5Functionally obsoleteGoodGoodGood18370
October 200378.1Functionally obsoleteGoodGoodGood18910
November 200178.6Functionally obsoleteGoodGoodGood18300
March 200078.8Functionally obsoleteGoodGoodGood17990
May 199878.0Functionally obsoleteGoodGoodGood19070
June 199880.5Functionally obsoleteGoodGoodGood15850
December 199585.0Not deficientGoodVery GoodVery Good16000
October 199386.0Not deficientGoodVery GoodVery Good14650
December 199185.7Not deficientGoodVery GoodVery Good15000