Share:

FM 1184 over ROBERTSON CREEK

Map 

Coordinates:
+33.52306, -95.58649
33°31'23" N, 95°35'11" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FM 1184 over ROBERTSON CREEK
Structure number:011390131901003
Location:0.2 MI E OF SH 19
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:24.9 ft. [7.6 m]
Total length:49.9 ft. [15.2 m]
Roadway width between curbs:19.4 ft. [5.9 m]
Deck width edge-to-edge:21.3 ft. [6.5 m]
Owner:State Highway Agency [01]
Year built:1952
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 9 / H 10 [1]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2015 

Status:Open, no restriction [A]
Average daily traffic:450 [as of 2011]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:20.8 tons [18.9 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:61.8
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$3,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
January 201561.8Functionally obsoleteGoodGoodSatisfactory450
January 201361.8Functionally obsoleteGoodGoodSatisfactory450
December 201060.9Functionally obsoleteGoodGoodSatisfactory460
February 200961.0Functionally obsoleteGoodGoodSatisfactory320
April 200755.9Functionally obsoleteGoodGoodSatisfactory410
June 200555.9Functionally obsoleteGoodGoodSatisfactory380
July 200358.7Functionally obsoleteGoodGoodSatisfactory340
May 200158.7Functionally obsoleteGoodGoodSatisfactory310
April 199969.4Functionally obsoleteGoodGoodSatisfactory310
April 199757.4Not deficientGoodGoodFair330
September 199668.4Not deficientGoodSatisfactorySatisfactory330
March 199568.4Not deficientGoodSatisfactorySatisfactory280
June 199364.1Not deficientGoodSatisfactorySatisfactory340
April 199164.1Not deficientGoodSatisfactorySatisfactory360