Share:

RBTS BRNCH RD P-4 over W FRK TRINITY RIVER

Map 

Coordinates:
+33.40008, -98.25826
33°24'00" N, 98°15'30" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:RBTS BRNCH RD P-4 over W FRK TRINITY RIVER
Structure number:021200AA0180001
Location:3.8 MI N FROM FM 2190
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:26.9 ft. [8.2 m]
Total length:55.1 ft. [16.8 m]
Roadway width between curbs:11.8 ft. [3.6 m]
Deck width edge-to-edge:13.1 ft. [4.0 m]
Owner:County Highway Agency [02]
Year built:1946
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2015 

Status:Posted for load [P]
Average daily traffic:50 [as of 2009]
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:33.7 tons [30.6 metric tons]
Inventory rating:22.8 tons [20.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:64.9
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$1,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
January 201564.9Functionally obsoleteGoodSatisfactorySatisfactory50
January 201364.9Functionally obsoleteGoodGoodSatisfactory50
January 201165.2Functionally obsoleteGoodGoodSatisfactory50
January 200965.2Functionally obsoleteGoodGoodSatisfactory50
January 200765.2Functionally obsoleteGoodGoodSatisfactory50
January 200564.9Functionally obsoleteGoodGoodGood50
January 200364.9Functionally obsoleteGoodGoodGood50
January 200149.1Functionally obsoleteGoodGoodGood50
January 199949.1Functionally obsoleteGoodGoodGood50
April 199749.1Functionally obsoleteVery GoodGoodGood50
February 199549.1Functionally obsoleteVery GoodGoodGood50
February 199358.9Not deficientVery GoodVery GoodVery Good50
February 199158.9Not deficientVery GoodVery GoodVery Good50