Share:

I-5 over EXP S-W RAMP BR

Map 

Coordinates:
+47.62833, -122.32667
47°37'42" N, 122°19'36" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I-5 over EXP S-W RAMP BR
Structure number:0006800H0000000
Location:2.1 N JCT I-90
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:38.1 ft. [11.6 m]
Total length:743.1 ft. [226.5 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:25.6 ft. [7.8 m]
Vertical clearance above deck:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:21
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:4,459 [as of 2007]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.2 tons [74.7 metric tons]
Inventory rating:48.5 tons [44.1 metric tons]
Sufficiency rating:89.5
Estimated cost of work:$270,000

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:33,081 [as of 1994]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.2 tons [74.7 metric tons]
Inventory rating:48.5 tons [44.1 metric tons]
Sufficiency rating:87.7
Estimated cost of work:$270,000

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:10,060 [as of 1976]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:54.5 tons [49.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:90.2
Estimated cost of work:$1,116,000