Share:

IH RAMP IH 94WBL-U over LAND

Map 

Coordinates:
+43.02996, -87.96953
43°01'48" N, 87°58'10" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:IH RAMP IH 94WBL-U over LAND
Structure number:B40004000040000
Location:0.2M S JCT IH 94 TO W
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:61.0 ft. [18.6 m]
Total length:171.9 ft. [52.4 m]
Roadway width between curbs:24.9 ft. [7.6 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Owner:State Highway Agency [01]
Year built:1959
Year reconstructed:1998
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:139,500 [as of 2007]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:55.2 tons [50.2 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:90.5

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:6,380 [as of 1996]
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:55.2 tons [50.2 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:94.4

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:5,200 [as of 1970]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:55.4 tons [50.4 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:94.6
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]