CTH E EB SILVER over STH 145-W FOND DU LAC AV
Map
Coordinates:
+43.11967, -88.0124143°07'11" N, 88°00'45" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | CTH E EB SILVER over STH 145-W FOND DU LAC AV |
| Structure number: | B40025300000000 |
| Location: | 1.1M E JCT USH 41 |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Minor Arterial (Urban) [16] |
| Length of largest span: | 94.2 ft. [28.7 m] |
| Total length: | 262.2 ft. [79.9 m] |
| Roadway width between curbs: | 36.1 ft. [11.0 m] |
| Deck width edge-to-edge: | 44.6 ft. [13.6 m] |
| Vertical clearance below bridge: | 15.4 ft. [4.7 m] |
| Skew angle: | 43° |
| Owner: | State Highway Agency [01] |
| Year built: | 1964 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 4 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Low slump Concrete [4] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 11,800 [as of 2007] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 62.4 tons [56.7 metric tons] |
| Inventory rating: | 32.1 tons [29.2 metric tons] |
| Sufficiency rating: | 81.5 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 14,140 [as of 1979] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 62.4 tons [56.7 metric tons] |
| Inventory rating: | 32.1 tons [29.2 metric tons] |
| Sufficiency rating: | 93.8 |
| Recommended work: | Bridge deck replacement with only incidental widening. [37] |
| Estimated cost of work: | $716,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 14,140 [as of 1979] |
| Deck condition: | Poor [4 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Serious [3 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 69.3 tons [63.0 metric tons] |
| Inventory rating: | 37.6 tons [34.2 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 47.6 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $1,010,000 |